XLPE power cable
sales@xlpepowercable.com +86-13731126075
HOME > NEWS > 3.6/6(7.2)KV XLPE Power Cable

3.6/6(7.2)KV XLPE Power Cable

3.6/6(7.2)KV XLPE Power Cable


1.Medium voltage 3.6/6 KV
2.Copper Conductor single core
3.Competitive price
4.More than 20 year factory
5.OEM order taken

1. Application Standards

IEC60502-2009 Power cables with extruded insulationand their accessories for rated voltages from 1kv(Um=1.2kv) up to 30kn(Um=36kv)

 

2. Applications

- Rated voltage from Uo/U(Um)3.6/6(7.2)KV to26/35(40.5)KV

-Armored cable is suitable for burying in ground.Able to bear external mechanical force but not large pulling force

-None armored cable suitable for layingindoors and outdoors. Able to bear a certain traction during installation, butnot external mechanical forces. Laying single core cable in magnetic ducts isnot allowed.

-

3. Model description.

Model No. of cores Rated Voltage Uo/U(Um)
3.6/6(7.2)6/6(7.2) 6/10(12) 8.7/10(12) 8.7/15(17.5) 12/20(240) 18/30(36) 26/35(40.5)
Cross-section Area Ranges (mm²)
YJV YJV22 1 35~630 35~630 35~630 50~630
YJLV YJLV22 1 35~630 35~630 35~630 50~630
YJV YJV22 3 35~300 35~300 35~300  
YJLV YJLV22 3 25~300 25~300 25~300  

 

 

Tips:

Our Chinese nominal way to name the cable:

YJV stands for Cu conductor XLPE insulatedPVC sheathed Power Cable

YJLV stands for Al conductor XLPE insulatedPVC sheathed Power Cable

The subscript 22 is stands for Steel Tapearmored Power Cable

Then subscript 33 is stands for Steel Wirearmored Power Cable

 

4. Installation

-The long time operating temperature shallnot exceed 90°C, Conductorshort circuit temperature for 5 seconds shall not exceed 250°C.

-Installation temperature requires above 0°C,

-The bending radius shall not less than 10time of the cable’s O.D.

 

5. Technical Data Sheet FYI.

 

Rated Voltage Uo/U(Um) 0.6/1(1.2) 3.6/6(7.2) 6/6(7.2) 6/10(12) 8.7/10(12) 12/20(24) 18/30(36) 21/35(40.5) 26/35(40.5)
D.C.Resistance of core
(Ω/km)
According to IEC228A-82
Partial discharge test(PC)
at 1.73Uo not greater than
  20 10
Power frequency withstaand
voltage test for 5 minutes
(KV)
3.5 11 15 15 22 30 45 53 65
Power frequency voltage
test for 5 minutes
(KV)
2.4 14.4 24 24 34.8 48 72 84 104
Hot set test for insulation
200°C with presure20N/cm² in15 minutes
Max.elongation at load %
Max.permanent elongation after cooled%
175
15
Partial discharge after be bent by three times and heat cycled at 1.73Uo not greater than 20 10
tg δ
Test at room temperature at Uo,not greater than
between 0.5 Uo and 2 Uo,not greater than
** ** ** 40×10-4
20×10-4
tg δ at 2KV
at ambient temperature,not greater than
at max.rated temperature not greater than
** ** ** 40×10-4
80×10-4
Conductor to be heated tupto the temperature 5°C higher than that of operating for long period
Heat shock(±10 time)(KV),not break down
** 60 75 75 95 125 170 200 250

 

we are one of top electric cable manufacture in north of china,main product include xlpe power cable,armoured cable,swa cable,single core cable,2 3 4 core armoured cable.

Copyright ©2016 XLPE power cable site map site map html
Links: XLPE insulated power cable - XLPE cable - armoured power cable - 3 core armoured cable - 4 core armoured cable - xlpe insulated cable - Copper Conductor XLPE Power Cable - armoured power cable - overhead cables - XLPE swa pvc cable - aerial bundled cable - PVC insulated cable - CU/XLPE/SWA/PVC Cable - 11kv xlpe power cable - lower voltage power cable - 33kv xlpe power cable - medium voltage xlpe power cable - rubber welding cable - rubber cables - rubber seal strip - rubber welding cables - epdm seal strip - non woven bag - pp woven bag -