Ruishi Drill bits
sales@xlpepowercable.com +86-13731126075
HOME > PRODUCTS > XLPE Insulated Power Cable > 300mm2 Copper Conductor XLPE Power Cable
300mm2 Copper Conductor XLPE Power Cable

300mm2 Copper Conductor XLPE Power Cable

Details

300mm2 Copper Conductor XLPE Power Cable


XLPE Insulated Power Cable,
XLPE power cable,
Copper Conductor XLPE Insulated Power Cable,

300mm2 Copper Conductor XLPE Power Cable -Application:
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Power cables for power networks, underground, outdoors and in cable ducting.

 xlpe power cable

Standards: BS6622, BS EN/IEC 60228,IEC60502.2

Conductor: Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)

Conductor screen: Semi-conducting material

Insulation: XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655

Insulation Screen: Semi-conducting material

Metallic Screen: Individual and overall copper tape screen to BS6622

Filler: PET (Polyethylene Terephthalate) fibres

Separator: Binding tape

Bedding: PVC (Polyvinyl Chloride) Type TM1 to BS7655

Armouring:

Single Core: Aluminium Wire Armoured (AWA)

MultiCore: Steel Wire Armoured (SWA)

Sheath: PVC (Polyvinyl Chloride) Type TM1 to BS7655

Colour: Red or Black

 

300mm2 Copper Conductor XLPE Power Cable - Using features:

1. Rated voltage: Uo/U:3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).

2. No. of core: Single core or three cores.

3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250℃.

4. D.C. resistance of the conductor complies with the stipulations of 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).

5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.

6. The cable is laid without horizontal drop limit.

7. Working Frequency Voltage Test: 3.5Uo/5min without puncture.

8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.

9. Minimum Bending Radius

300mm2 Copper Conductor XLPE Power Cable

Single core - Fixed: 15 x overall diameter

3 core - Fixed: 12 x overall diameter

(Single core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)

Note:

The single core armoured cables are used for D.C. system only. If used for A.C. system, the magnetic isolation should be applied on the steel armoire wires of non-magnetical materials should be used.

XLPE Insulated Power Cable,
XLPE power cable,
Copper Conductor XLPE Insulated Power Cable,



we are one of top electric cable manufacture in north of china,main product include xlpe power cable,armoured cable,swa cable,single core cable,2 3 4 core armoured cable.

Copyright ©2016 XLPE power cable site map site map html
Links: XLPE insulated power cable - XLPE cable - armoured power cable - 3 core armoured cable - 4 core armoured cable - xlpe insulated cable - Copper Conductor XLPE Power Cable - armoured power cable - overhead cables - XLPE swa pvc cable - aerial bundled cable - PVC insulated cable - CU/XLPE/SWA/PVC Cable - 11kv xlpe power cable - lower voltage power cable - 33kv xlpe power cable - medium voltage xlpe power cable - rubber welding cable - rubber cables - rubber seal strip - rubber welding cables - epdm seal strip - non woven bag - pp woven bag -

ASK FOR QUOTE

Your name

Email

Message