Aluminum Conductor XLPE Insulated Power Cable

Aluminum Conductor XLPE Insulated Power Cable

Details

Aluminum Conductor XLPE Insulated Power Cable

XLPE Insulated power cable,
Al xlpe swa pvc power cable,

Aluminum Conductor XLPE Insulated Power Cable

Application:
 
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Power cables for power networks, underground, outdoors and in cable ducting
 
Aluminum Conductor XLPE Insulated Power Cable  Construction
 
Standards: BS6622, BS EN/IEC 60228,IEC60502.2
Conductor: Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
Conductor screen: Semi-conducting material
Insulation: XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655
Insulation Screen: Semi-conducting material
Metallic Screen: Individual and overall copper tape screen to BS6622
Filler: PET (Polyethylene Terephthalate) fibres
Separator: Binding tape
Bedding: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Armoring:
Single Core: Aluminum Wire Armored (AWA)
MultiCore: Steel Wire Armored (SWA)
Sheath: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Color: Red or Black
 
Aluminum Conductor XLPE Insulated Power Cable Using features:
 
1.Rated voltage: Uo/U:3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
2. No. of core: Single core or three cores.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250ºC.
4. D.C. resistance of the conductor complies with the stipulations of 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit.
7. Working Frequency Voltage Test: 3.5Uo/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
9. Minimum Bending Radius
Single core - Fixed: 15 x overall diameter
3 core - Fixed: 12 x overall diameter
(Single core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)

Aluminum Conductor XLPE Insulated Power Cable



China Type Description Application
Cu Al
YJV YJLV XLPE insulation PVC sheath power cable (Cu/XLPE/PVC) To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside 
YJY YJLY XLPE insulation PE sheath power cable (Cu/XLPE/PE)
YJV22 YJLV22  XLPE insulation, steel tape armor,  PVC sheath power cable
(Cu/XLPE/PVC/STA/PVC)
To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force.
YJV23 YJLV23 XLPE insulation, steel tape armor,  PE sheath power cable
(Cu/XLPE/PVC/STA/PE)
YJV62 YJLV62 XLPE insulation,  no  magnetism steel tape armor,  PE sheath power cable
YJV32 YJLV32 XLPE insulation, thin steel-wire  armor,  PVC sheath power cable
(Cu/XLPE/PVC/SWA/PVC)
Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint
.
YJV72 YJLV72 XLPE insulation, have no the magnetism thick steel-wire  armor,  PVC sheath power cable
YJV42 YJLV42 XLPE insulation, thick steel-wire  armor,  PVC sheath power cable Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.
 
 
Type Description Application
Cu Core Al Core
YJV
ZR-YJV
YJLV
ZR-YJLV
Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable
Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable
Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force.
YJV22
ZR-YJV22
YJLV22
ZR-YJLV22
Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable
Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable
Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force.
YJV32
ZR-YJV32
YJLV32
ZR-YJLV32
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable
Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force.
YJV42
ZR-YJV42
YJLV42
ZR-YJLV42
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable
Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force.
 

we are one of top electric cable manufacture in north of china,main product include xlpe power cable,armoured cable,swa cable,single core cable,2 3 4 core armoured cable.

Copyright ©2016 XLPE power cable site map site map html
Links: XLPE insulated power cable - XLPE cable - armoured power cable - 3 core armoured cable - 4 core armoured cable - xlpe insulated cable - Copper Conductor XLPE Power Cable - armoured power cable - overhead cables - XLPE swa pvc cable - aerial bundled cable - PVC insulated cable - CU/XLPE/SWA/PVC Cable - 11kv xlpe power cable - lower voltage power cable - 33kv xlpe power cable - medium voltage xlpe power cable - rubber welding cable - rubber cables - rubber seal strip - rubber welding cables - epdm seal strip - non woven bag - pp woven bag -